AT – Series User’s Manual
MKTF-205 06/12
AT-500, AT-1000 SYSTEM IDENTIFICATION
FIGURE 1A
NUMBER IDENTIFICATION
1. Solenoid Valve – Turns On/Off Feed Water
2. 5 Micron Sediment – Removes particulates
3. 10 Micron Carbon Block – Chlorine reduction
4. Pressure Gauge - Measures feed pressure
5. Pressure Gauge - Measures pressure after filters
6. Control Switch - Controls RO system
7. Recycle Valve – Recycles concentrate back to feed (if applicable)
8. Concentrate Valve – Controls flow of concentrate (waste) water to the drain
9. RO Pump - Pressurizes RO system
10.Flow Meter - Measures flow of permeate water
11.Flow Meter - Measures flow of concentrate (waste) water
12.Flow Meter - Measures flow of concentrate recycle water (if applicable)
13.Pressure Gauge – Measures pump discharge pressure
14.Pressure Switch – Turns the pump off at less than 15 PSI feed pressure
15.Permeate Check Valve- Protects membranes from back pressure
16.Pressure Vessels – Houses Membrane Elements