Form 5554E
Installation, Operation and
Maintenance Instructions
for AC Induction Motors
56- 6800 Frames (NEMA)
63 – 280 Frames (IEC)
MARATHON ELECTRIC
Contact Motor Customer Service at:
Phone:
(715) 675-3311
www.marathonelectric.com
Page view 0
1 2 3 4 5 6 ... 14 15

Summary of Contents

Page 1 - Maintenance Instructions

Form 5554E Installation, Operation and Maintenance Instructions for AC Induction Motors 56- 6800 Frames (NEMA) 63 – 280 Frames (IEC) MARATHON ELE

Page 2 - Table of Contents

WARNING: LOOSE & ROTATING PARTS HAZARD Before proceeding read Section 1-2 on Mechanical Safety. Failure to follow the instructions in Sectio

Page 3

Nameplate Ambient Temperature above 65°C (150°F): Dow Corning DC44 or equivalent, a special high temperature grease is required. Note

Page 4

4.2.4 LUBRICATION PROCEDURE: (For Motors with Regreasing Provisions) CAUTION: BEARING DAMAGE WARNING Added grease must be compatible with

Page 5

4.3.2 Motor Trouble-shooting Cause / Corrective Action - Table 4-5 Issue: Likely Cause: Corrective Action: Motor fails to start upon initial install

Page 6

E.) Motor is started too frequently See section 3.4.5.3 F.) Supply voltage too low, too high, or unbalanced (1) Ensure that steady state supply vo

Page 7 - 4, 6, or 8

B.) Input voltage exceeds limit Verify that voltage to the motor terminals is within limits (see section 3.4.1.3). C.) Power surge to motor (cause

Page 8

SAFETY INSTRUCTIONS This is the safety alert symbol. It is used to alert you to potential personal injury hazards.

Page 9

4.1.1 Ventilation 4.1.2 Insulation 4.1.3 Electrical Connections 4.2 Lubrication and Bearings 4.2.1 Grease Type 4.2.2 Bearing Operating Temperatu

Page 10

2.3.1 BEARING LUBRICATION: Bearings are grease packed at the factory; relubrication upon receipt of motor or while in storage is not necessary.

Page 11

mounting a rigid base (footed) motor vertically is the responsibility of the installer. VERTICAL SHAFT DOWN: Most standard horizontal motors

Page 12

Figure 1 BELT SPEED (Ft/min) =12inches Dia Sheavex 3.14 x RPM Shaft )( 3.3.4.2 Number of Belts In general, use the fewest number of b

Page 13

Table 3-3 Recommended Minimum Sheave Diameters, Belt Type, Number of Belts and Deflected Force1200 rpm 1800 rpm 3600 rpm Motor Hp Min

Page 14

to Table 3-5 values. Definite purpose VFD motors may accommodate longer cable lengths. For additional information contact motor manu

Page 15

3.4 ELECTRICAL CONNECTIONS: WARNING: ELECTRICAL HAZARDS Before proceeding read Section 1-1 on Electrical Safety. Failure to follow th